Pyrolysis Deemed a Viable Alternative to Incinceration
Researchers at the University of York have concluded that PyroPure (UK) technology has the potential to transform the way in which hazardous waste is destroyed in clinical environments and say pharmacists, manufacturers and hospitals throughout the UK should consider trialling the system. The announcement follows a six month Innovate UK-funded Knowledge Transfer Partnership project in […]
England’s trash generating Danish heat
Power in Denmark is increasingly being generated in plants burning waste imported from England. The practice is being called an economical and environmental boon on both sides of the equation. The AVØ incinerator in Frederikshavn produces heating and power for the area by burning trash from England. “It is mainly construction waste like pieces of […]
INCINERATOR SPECIFICATION Capacity UPTO 20 kg/hr
Size: 940 x860x2700 mmMaterial: STAINLESS STEEL STACK, REFRACTORY CONCRETE LINING SPECIAL INSULATION MATERIALWith burner: 15 C 20 KWTemperature: PRIMARY CHAMBER = 800°C AND SECONDARY CHAMBER = 850 – 1200° CSufficient heat generation for secure and complete combustion 600-800 °C in the first chamber and >1000 °C in the second chamberEasy transportation on standard EURO-pallets Constructed in a modular fashion easy on-site movement and assembly with a minimum of equipment and technical skills;For the destruction of problematic waste like sharps, amputates and body parts, wet or moist matter; Off-gas quality: moderate smoke emissions during one quarter of the total incineration time; no visible emission during three quarters. AS PER INTERNATIONAL STANDARDS The remaining ash approximately 5-10% in weight and below 1% in volume of the original waste AS PER INTERNATIONAL STANDARDS Chimney height at least 5 m above the incinerator 5m ABOVE FROM THE GROUNDTemperature resistance of the lining at least 1,200 °C
Ebola: Southport firm leading the fight in global health crisis
Sales and marketing manager Paul Niklas said they had more than a hundred orders from global organisations and aid agencies, including the United Nations and the Red Cross. He also said most of their workforce was dedicated to manufacturing the incinerators. The larger ones can burn up to 1,000kg of waste an hour, smaller ones […]
Controlled air medical waste incinerator designed for incineration of bio-medical waste
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical SpecsCombustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber Temperature Monitoring Yes Average ash residue (%) 3% Thermostatic Device Yes 1000l diesel flue tankVenture gas scrubberHydraulic Ram Feeding SystemDiesel Powered Large Incinerator Minimum Specification Required Standards1) Bidder or Manufacturer ISO 9001 Certified2) Respecting international emission standardsElectrical characteristics3) A 230V, 60Hz single-phase electrical source.4) Protections against over-voltage and over-current line conditions.5) Compliance with applicable Ghanaian standards and regulations.Operational characteristics6) Two-stage incineration with dual chamber combustion7) Burn rate: 15 – 20 Kg/h8) Capacity: not less than 130 L9) Concentrations of most pollutants in stack gases below detection limits10) Diesel fuel11) Electronic system control12) Easy to operate and minimal training13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION
Supply of Inclinators for Interim Arrival Domestic Terminal Project
CMC Services for Inclinators for 3 years including all spares, consumables, Skilled Manpower, tools and tackles all complete. As per Scope attached as AnnexureDesign, Manufacture, Supply, delivery to site, installation, testing & commission of All weather proof Passenger Inclinators in accordance to the Scope and outline specifications mentioned in AnnexureSpesifikasi Incinerator 100kg/jam Spesifikasi dan Daftar Material Dimensi dan Power Capacity Nama Barang : INCINERATORType / Model : PWR-INC-KMN 10Kapasitas : 100kg/Jam (1 m3)Length : 288 cm Width : 147 cm Height : 163 cm Height of Chimney std : 700 cm TOTAL WEIGHT : 8000 kg Panel – timer : Digital Included Auto AlarmFinishing : Hot endured paint Fuel tank : 200 Liter Covering Element from steel : 3-8mm Banyaknya Burner : 2 pcs Banyaknya Blower : 2 pcs Max. Fuel consumption : 15-30 Liter/Jam Max. Elektric consumption : 1100 Watt Bahan bakar : Kerosene / Diesel (solar) Voltage : 220 V / 1 phase / 50 Hz Material 1. PANEL CONTROL Type : Digital Buatan : Local KAMINE ( Panel dan Incinerator satu Merek)Voltage : 220 V / 1 phase / 50 Hz Safety operator : Emergency Stop System : Microkontroller Pengoperasian : Semi AutomaticTemperatur control : Digital Coupler TypeControl panel : Manual dan automaticTipe : Self Standing Type / Wall Mounted TypeMaterial : Mild steelThermocontrol : 2 (Dua) 1200 ºCSet of timer : 0- 2 jamTombol saklar : on/off 2. CONTRUCTIONS Fire Brick : SK 34Castable : R 16Castable : R 14Isolator : Insulating Brick serat tahan panas Keramik 1.450 ⁰ CElement from steel : 3-8 mmFinishing : Cat Fetalit coating, Epoxy Resin (hot-endured paint)Total berat keseluruhan : 8.000 kgKetebalan Dinding Dalam : 21 Cm 3.DIMENSION OF CHAMBER (Dimensi Ruang Bakar) Chamber 1 Ruang Bakar Utama : 100 x 100 x 98 cm = 980.000 cm3 = 0.98 m3Chamber 2 Ruang Bakar Kedua: 40 x 100 x 98 cm = 392.000 cm3= 0.39 m3 4. EXHAUST STACK (Chimney) – Diameter (inch): Ø 10″, 8″-Panjang: 700 cm (7 m) dari permukaan tanah -Cerobong pertama dengan system Cor tipe MWHT-Material Mild steel ( Baja Hitam ) 5. INSTRUMENTATION & KONTROL 1. Suhu Control: Optimal – Model: Digital – Jumlah (unit): 2 (dua) unit – Kontrol Mode: On-Off 2. Power Supply (volt / fase / herts): 15A / 220 V / 1 Phase / 50 Hz 3. Panel kandang: Mild Steel + powder coating 4. Thermocouple: K – Jumlah: 2 (dua) unit – Bahan: Stainless Steel + Ceramic 5. Timer: 0-2 Jam 6. De-ashing: Manual 7. System pembuangan Abu 2 unit 6. PINTU Pintu : Baja ringan dan Linning dengan castable System : Double lock system ( penguncian ganda ) 7. AIR SUPPLY SYSTEM Model / Type: fan sentrifugal 3 “Kapasitas (m3/minute): 3.000 m3/mntStatis Tekanan (mmAq): 98 mmAqPower : 200 watt/unitJumlah (unit): 2 (dua) 8. FUEL SYSTEM Pembakaran Burner:Type: Gun type OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower : 250 wattJumlah unit : 1 unit Type: Gun type OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower : 250 wattJumlah unit : 1 unit 9. THERMOCOPLERuang bakar pertama dan keduaTipe : KProtective tube : Stainless steel + ceramicMax. temperature : 1200 ºCJumlah : 2 unitSistem pemberian umpan : ManualSistem pengeluaran hasil : Manual 10. TANGKI BAHAN BAKARMaterial : Mild steel Kapasitas : 200 liter Horizontal Autoclave 155 LitersSterilizing chamber: Steam-heated via double back wall with integrated steam generatorDoor and lock: Hinged door with quick lock and safety lockDoor seal: Blow-out design, even closure, automatic return without vacuum systemTemperature measurement technology: 2 independent sensors for controlling the steam generator + 1 sensor for sterilizing chamberPreheating keySecurity key switch saves program settingsSterilization phase indicatorsPressurized-air supply: integrated Compressor for door control circuit and pneumatic set valvesFeed water consumption per batch 0.7 to 5.6 litersCooling water consumption per batch for spent-steam condenser 10–25 l at temperatures 15 °CWater-level control: Within the double back wallLow-water safety fuse: Heater Over temperature monitorSterile venting: Membrane filter 0,2um, 0.1 m² hydrophobic, steam-sterillisable, retention 99.5%Control circuits: separate for heater and door seal, process control and monitoringTimer Program start by date and timeSelectable Acoustic alarm at program endTransport security device for door Three Autoclave able (Polypropylene or stainless steel) Pans 5-10L
Controlled air medical waste incinerator designed for incineration of bio-medical waste
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. ) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption […]